ENDORSER CRCO - COBALT CHROMIUM CORONARY STENT SYSTEM

"Endorsing hearts with flexibility and inventions"
Endorser CrCo is a superior combination of innovation in Technology and Experience deploying strength of cobalt chromium with futuristic technology of hybrid design to meet all PCI needs.
The Endorser CrCo coronary stent System includes L605 Cobalt Chromium (Co - Cr alloy) stent located on balloons catheter between two platinum iridium radio opaque markers bands. The Endorser CrCo is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease in de novo coronary artery lesion in native coronary arteries with a reference vessel diameter of 2.50 mm to 4.0 mm and a lesion length 08 mm to 40 mm. The Endorser CrCo is intended for use in patients eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA).
Designed to prevent recoil with thin struts and high radial strength - The metallic strength of Chromium Cobalt alloy allows thinner strut in the design thus flexibility. Hybrid Design prevents elastic recoil.
High vessel conformance and low edge effect - Hybrid Design of close cell at the Edges and open cells at the middle and S-shaped links in at every 3 crowns of open cell adds to flexibility with preserved vessel support. No Dog-boning on edges prevents insult of arterial tissue and consequent edge effect.
Designed to prevent recoil with thin struts and high radial strength - The metallic strength of Chromium Cobalt alloy allows thinner strut in the design thus flexibility. Hybrid Design prevents elastic recoil.

Technical Specification


No Title Description

1

Device Description

Cobalt Chromium coronary stent mounted on RX PTCA balloon catheter

2

Available Stent Length

8 mm,12 mm,16 mm, 20 mm, 24 mm, 28 mm, 32 mm , 36 mm , 40 mm

3

Available Stent Diameter

2.50 mm, 2.75 mm, 3.00 mm, 3.50 mm, 4.00 mm

4

Stent Material

Surgical grade L605 cobalt chromium alloy

5

Stent Design

Hybrid Stent has a unique hybrid cell design comprising of an intelligent mix of open and close cell designs resulting in a structure which provides excellent radial strength with a high degree of flexibility

6

Crimped (crossing) Profile

< 1 mm

7

Strut Thickness

0.065 mm

8

Radial Strength

> 1.6 N

9

Elastic Recoil

< 5 %

10

Foreshortening

< 0.25 %

11

Ferromagnetism

Non ferromagnetic

12

Radio-opacity of struts

High

13

Radio-opacity of markers

Very High

14

Ballon Compliance

Semi-compliant

15

Entry Profile

0.01 mm

16

Catheter Compatability

5 fr

17

Guide wire compatability

0.014 mm

18

Ballon Winging

Trifold

Low crimped and entry profiles - The entry profile of catheter tip is < 0.01 mm with graduated tip for smooth and safe crossing of the lesion.
Low bending stiffness - Attribute to the stent design and delivery system properties; the stent is highly flexible and easy to navigate into even difficult anatomy such as tortuous vessels and acute curved vessels.

Ordering Information


DM 8 12 16 20 24 28 32 36 40

2.50

EC25008

EC25012

EC25016

EC25020

EC25024

EC25028

EC25032

EC25036

EC25040

2.75

EC27508

EC27512

EC27516

EC27520

EC27524

EC27528

EC27532

EC27536

EC27540

3.00

EC30008

EC30012

EC30016

EC30020

EC30024

EC30028

EC30032

EC30036

EC30040

3.50

EC35008

EC35012

EC35016

EC35020

EC35024

EC35028

EC35032

EC35036

EC35040

4.00

EC40008

EC40012

EC30016

EC40020

EC40024

EC40028

EC40032

EC40036

EC40040







Related Products

Our practice prides itself on providing the very finest level of service, from a simple filling to complex cosmetic dentistry.

  • Endorser SS316L Coronary Stent System
    stents

  • Enovo - Everolimus Eluting Coronary Stent System
    stents

  • Sinew – Sirolimus Eluting Coronary Stent System
    stents

  • Inspire – Paclitaxel Eluting Coronary Stent System
    stents

Live Customizer

Choose Color-skin