Veritas Bioventions

Sinew ™ - Sirolimus Eluting Coronary Stent System

New dimensions of strength of experience

Sirolimus Eluting Coronary Stent on Cobalt Chromium L605 Platform mounted on Rapid Exchange delivery system

 

The Sinew Coronary Stent System includes loading and elusion of Sirolimus Drug in a controlled fashion on L605 Cobalt Chromium (Co – Cr alloy) Platform, stent located on balloons catheter between two platinum iridium radio opaque markers bands. The drug is encapsulated with several biodegradable polymers and loaded on the stent through a proprietary coating technology. The Sinew is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease in de novo coronary artery lesion in native coronary arteries with a reference vessel diameter of 2.25 mm to 4.0 mm and a lesion length ≤ 40 mm. The Sinew is intended for use in patients eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA).

Endorser CrCo platform is engineering marvel with unique features to make navigation of the stent easy and safe even through even Challenging anatomy. It has unmet combination of radial strength, ease of the side branch access, vessel support and flexibility.

Hybrid Cell Design
Endorser CrCo is Hybrid cell design that has close cells at the end and open cells in middle.

Reduced injury of edges
Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the " edge effect " of the stent.

Reduced injury of edges
Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the " edge effect " of the stent.

Excellent side branch access
Link at every third crest in the middle segment that would usually face artery makes a clear wide opening for hardware to pass through in side branch.

Low bending stiffness ( High Flexibility )
Attribute to the stent design and delivery system properties, the stent is highly flexible and easy to navigate difficult anatomy.

Technical Specification

NO Title Description
1Device DescriptionSirolimus drug with biodegradable polymer coating coronary stent system. Cobalt Chromium coronary stent platform.
2Available Stent Length8 mm,12 mm,16 mm, 20 mm, 24 mm, 28 mm, 32 mm , 36 mm , 40 mm
3Available Stent Diameter2.50 mm, 2.75 mm, 3.00 mm, 3.50 mm, 4.00 mm
4Stent MaterialSurgical grade L605 cobalt chromium alloy
5Stent DesignHybrid Stent has a unique hybrid cell design comprising of an intelligent mix of open and close cell designs resulting in a structure which provides excellent radial strength with a high degree of flexibility
6Radio-opacity of strutsHigh
7Radio-opacity of markersVery High
8Ballon ComplianceSemi-compliant
9Entry Profile0.01 mm
10Catheter Compatability5 fr
11Guide wire compatability0.014 mm
12Ballon WingingTrifold
13Distal Tracking forceLow

Ordering Information

DM 81216202428323640
2.50
SN25008
SN25012
SN25016
SN25020
SN25024
SN25028
SN25032
SN25036
SN25040
2.75
SN27508
SN27512
SN27516
SN27520
SN27524
SN27528
SN27532
SN27536
SN27540
3.00
SN30008
SN30012
SN30016
SN30020
SN30024
SN30028
SN30032
SN30036
SN30040
3.50
SN35008
SN35012
SN35016
SN35020
SN35024
SN35028
SN35032
SN35036
SN35040
4.00
SN40008
SN40012
SN30016
SN40020
SN40024
SN40028
SN40032
SN40036
SN40040