Everolimus Eluting Coronary Stent on Cobalt Chromium L605 Platform mounted on Rapid Exchange delivery system

The Enovo Coronary Stent System includes loading and elusion of Everolimus Drug in a controlled fashion on L605 Cobalt Chromium (Co – Cr alloy) Platform, stent located on balloons catheter between two platinum iridium radio opaque markers bands. The drug is encapsulated with several biodegradable polymers and loaded on the stent through a proprietary coating technology. The Enovo is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease in de novo coronary artery lesion in native coronary arteries with a reference vessel diameter of 2.25 mm to 4.0 mm and a lesion length ≤ 40 mm. The Enovo is intended for use in patients eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA).

Endorser CrCo platform is engineering marvel with unique features to make navigation of the stent easy and safe even through even Challenging anatomy. It has unmet combination of radial strength, ease of the side branch access, vessel support and flexibility.

Hybrid Cell Design
Endorser CrCo is Hybrid cell design that has close cells at the end and open cells in middle.

Reduced injury of edges
Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the " edge effect " of the stent.

Reduced injury of edges
Innovative hybrid design of Endorser inflation pressure of the balloon is evenly distributed even with uniform stent expansion. This reduces the " edge effect " of the stent.

Excellent side branch access
Link at every third crest in the middle segment that would usually face artery makes a clear wide opening for hardware to pass through in side branch.

Low bending stiffness ( High Flexibility )
Attribute to the stent design and delivery system properties, the stent is highly flexible and easy to navigate difficult anatomy.

Technical Specification

NO Title Description
1Device DescriptionEverolimus drug with biodegradable polymer coating coronary stent system. Cobalt Chromium coronary stent platform.
2Available Stent Length8 mm,12 mm,16 mm, 20 mm, 24 mm, 28 mm, 32 mm , 36 mm , 40 mm
3Available Stent Diameter2.50 mm, 2.75 mm, 3.00 mm, 3.50 mm, 4.00 mm
4Stent MaterialSurgical grade L605 cobalt chromium alloy
5Stent DesignHybrid Stent has a unique hybrid cell design comprising of an intelligent mix of open and close cell designs resulting in a structure which provides excellent radial strength with a high degree of flexibility
6Radio-opacity of strutsHigh
7Radio-opacity of markersVery High
8Balloon ComplianceSemi-compliant
9Entry Profile0.01 mm
10Catheter Compatibility5 fr
11Guide wire compatibility0.014 mm
12Balloon WingingTri-fold
13Distal Tracking forceLow
14Ballon ComplianceSemi-compliant

Ordering Information

DM 81216202428323640
2.50
EN25008
EN25012
EN25016
EN25020
EN25024
EN25028
EN25032
EN25036
EN25040
2.75
EN27508
EN27512
EN27516
EN27520
EN27524
EN27528
EN27532
EN27536
EN27540
3.00
EN30008
EN30012
EN30016
EN30020
EN30024
EN30028
EN30032
EN30036
EN30040
3.50
EN35008
EN35012
EN35016
EN35020
EN35024
EN35028
EN35032
EN35036
EN35040
4.00
EN40008
EN40012
EN30016
EN40020
EN40024
EN40028
EN40032
EN40036
EN40040